GTO 4000XL Instruction Manual © 091610 25
Generation 3 Visual Feedback
SYMPTOM DIAGNOSIS CHECK:
Status (clear)1 blink Cycle Terminal
Shorted
•Disconnectthepushbutton,keypad,intercomkeypad,or
any other accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,thentheproblemis
the accessory.
Status (clear) 2
blinks
Safety Terminal
Shorted
•Disconnecttheloopdetector,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 3
blinks
Exit Terminal
Shorted
•Disconnectexitwand,loopdetector,photobeam,orany
other accessory wired to this terminal.
•Tryremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 4
blinks
Shadow Terminal
Shorted
•Disconnecttheloopdetector,photobeam,oranyother
accessory wired to this terminal.
•Tryremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 5
blinks
Close Edge
Terminal Shorted
•Disconnecttheedgesensor,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 6
blinks
Open Edge
Terminal Shorted
•Disconnectedgesensor,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
RF (yellow) Flickers Receiving 318 MHz
RF
•Normaloperationwhenremoteorwirelesskeypadisused.
RF (yellow)OFF No 318 MHz RF
Received
•BatteryinRemote
•ProgramRemote
•AntennaReceiverConnections
•AntennaReceiver
Power (green)
ON
AC or Solar Power
Present
•NormalOperation
VOLTAGE RATINGS
18 Vac Transformer 18.0 to 22.0 Vac, 2200mA
10 W Solar panel (single) 18.0 to 22.0 Vdc 600 mA
* measure voltage at panel and control box.
12 V, 7 amp hour Battery 12.5 to 13.5 Vdc 7.0 Ah
or Two 12V, 7 amp hour Batteries if using solar power
*measure voltage at battery terminals with battery disconnected
Charging circuit 12.0 to 14.8 Vdc
*measure voltage at battery terminals with battery connected