Pro-Built Tools PB1200 Series Manual de instalación Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
16 GTO 4000XL Instruction Manual © 091610
Step 4
With the gate in the desired closed
position PRESS & HOLD the “LEARN
MAST LIMIT button on the control board
for 5 seconds.
Step 5
Press the transmitter button and
allow the gate to return to the fully
open position (arm fully retracted).
The gate closed position limit is now
programmed.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow
your gate to close. If the CLOSED
position is not correct or needs to be
changed, you will need to CLEAR your
CLOSED LIMIT settings and follow Steps
1-4 again.
CLEARING THE PROGRAMMED CLOSED
LIMIT SETTING:
If you make a mistake and set the limit
at the wrong position: press your
transmitter to return the gate to the fully
opened position, then press and hold
the “LEARN MAST LIMIT” button for 5
seconds. This will clear the memory for
the closed limit position. Repeat Steps
1-4.
Adjust the Stall Force Setting
The Stall Force potentiometer on the
control board controls the obstruction
sensitivity (or the amount of force the
operator will apply to an obstruction for
two (2) seconds before it automatically
stops and reverses direction).
IMPORTANT: For safety reasons
the stall force setting will need
to be adjusted for your particular
application.
The Stall Force potentiometer on the
control board operates like a volume
controlonaradio.Useasmallatblade
screwdriver to adjust the potentiometer.
Adjust the stall force from the MIN
position until the gate operates
smoothly without obstructing from its
own weight or wind conditions.
NOTE: you may need to increase the
stall force in cold temperatures due to
increased resistance from gate hinges.
Learn Master Limit
Button
1 2 3 4
ON DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
1 2 3 4
ON DIP
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
2ND OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
1 2 3 4
ON DIP
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
2ND OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
120 MIN MAX
120 MIN MAX
120 MIN MAX
120 MIN MAX
120 MIN MAX
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
AUTO CLOSE TIME STALL FORCE
OFF
PUSH
SIMULT.
120 MIN MAX
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
1 2 3 4
ON
OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
MIN MAX
STALL FORCE
Vista de pagina 25